Description: Lynx Smart BMS 1000 Battery Management System for Lithium Smart Batteries The Lynx Smart BMS is a dedicated Battery Management System (BMS) for the Victron Lithium Battery Smart batteries. These batteries are Lithium Iron Phosphate (LiFePO4) batteries and are available in 12.8 V or 25.6 V in various capacities. They can be connected in series, parallel, and series/parallel so that a battery bank can be built for system voltages of 12V, 24 V, or 48 V. The maximum number of batteries in one system is 20, which results in a maximum energy storage of 84 kWh in a 12 V and up to 102 kWh in a 24 V1) and 48 V1) system. Out of the various available BMSes, the Lynx Smart BMS is the most feature-rich and complete option and integrates seamlessly into the Lynx Distributor system. This model is a 1000 A (M10) version. Built-in 1000 A Contactor The contactor acts as a secondary safety system to protect the battery in case the primary controls (ATC, ATD, and/or DVCC) fail to disable loads and/or chargers when required and is also suitable as a remote controllable main system switch. Pre-charge Circuit In addition to the contactor, a built-in pre-charge circuit prevents high inrush currents when connecting a capacitive load such as a MultiPlus/Quattro or other inverter, eliminating the need for external pre-charging. Monitoring and Control Monitor and control the BMS via Bluetooth using the VictronConnect App or a GX device such as a Cerbo GX and the VRM Portal. A built-in battery monitor that operates similarly as the other Victron Energy battery monitors, provides data such as state of charge, voltage, current, historical data, status info, and more in real-time and with instant readout even without the need to connect to the BMS, allowing diagnostic at a glance. DVCC closed Loop Control as Well as ATC/ATD Contacts Compatible Victron inverters/chargers and solar chargers are automatically controlled via a connected GX device and DVCC. The ATC/ATD contacts can be used to control other chargers and loads that have a remote on/off port. Programmable Relay The relay can be used either as an alarm relay (combined with the pre-alarm) or to control an alternator via its external regulator (ignition cable). In Alternator ATC mode, the relay will only activate when the contactor is closed. Alternator ATC contact of the alternator opens first and then with a delay of 2 seconds the contactor. These 2 seconds ensure that the alternator is switched off before the battery is disconnected from the system. AUX Terminal The advantage of the onboard auxiliary power supply (1.1 A @ system voltage) is to provide power to specific loads (i.e. a GX device) after the BMS has shut down the loads in the event of a low cell voltage event. If no charge voltage is detected within 5 minutes, the BMS, including the AUX connection switches off. VE.Can and NMEA 2000 Data Communication VE.Can allows for easy connection (standard RJ45 network cable) and communication with a GX device. Since the CANbus protocol is based on NMEA 2000 (and J1939), it is easy to integrate into a marine network and feed a marine MFD with data (requires a VE.Can to NMEA 2000 micro-C male cable). Lynx Distributor Fuse Monitoring Read out the fuse status and receive an alarm in case a fuse is blown. The Lynx Smart BMS monitors up to 4 connected Lynx Distributors and their fuses via VictronConnect or a GX device 1) To reduce the required balancing time, we recommend using as many different batteries in series as possible for the application. 24 V systems are best built using 24 V batteries, and a 48 V system. This System Contains the Following Components:Lynx Distributor with 2 fused paralleled lithium-ion smart batteries.Lynx Smart BMS with BMS, contactor, and battery monitorA second Lynx distributor provides fused connections for inverter/charger(s), loads and chargers (additional modules can be added if more connections are needed)A Cerbo GX (or other GX device) to read out the Lynx Smart BMS and Lynx Distributor data. Power Specifications:Battery Voltage Range: 9 – 60 VDCMaximum Input Voltage: 75 VDCSupported System Voltages: 12, 24, or 48 VReverse Polarity Protection: NoMain Safety Contactor Continuous Current Rating: 1000 A continuousMain Safety Contactor Peak Current Rating: 1200 A for 5 minutes Power Consumption OFF Mode: 0.3 mA for all system voltagesPower Consumption in Standby Mode: Approximately 0.6 W (50 mA at 12 V)Power Consumption in ON Mode: Approx. 2.6 W (217 mA at 12 V) depending on the state of the relaysApproximately 4.2 W (350 mA at 12 V) depending on the state of the relaysMinimum Load Resistance for Pre-Charging: 10 Ω and above for 12 V systems, 20 Ω and above for 24 V and 48 V systemsAUX Output Maximum Current Rating: 1.1 A continuous, protected by resettable fuseAllow-to-Charge Port Maximum Current Rating: 0.5 A at 60 VDC, protected by a resettable fuseAllow-to-Discharge Port Maximum Current Rating: 0.5 A at 60VDC, protected by a resettable fuseAlarm Relay (SPDT) Maximum current Rating: 2 A at 60 VDC Connections:Busbar: M10 (Torque: 17 Nm)VE.Can: RJ45I/O: Removable multi-connector with screw terminalsBattery BTV Cables: Male and female circular 3-pole connector with M8 screw ring Up to 20 batteries can be connected in one system Lynx Distributor fuse monitoring (up to 4 modules) RJ10 (cable ships with each Lynx Distributor) Physical Specifications:Enclosure Material: ABSEnclosure Dimensions (h x w x d): 230 x 180 x 100 mmUnit Weight: 2.7 kgBusbar Material: Tinned copperBusbar Dimensions (h x w): 8 x 30 mm Environmental Specifications:Operating Temperature Range: -40 °C to +60 °CStorage Temperature Range: -40 °C to +60 °CHumidity Max.: 95 % (non-condensing)Protection Class: IP22 StandardsSafety: EN-IEC 63000:2018EMC: EN-IEC 61000-6-3:2007/A1:2011/AC:2012QMS: NEN-EN-ISO 9001:2015Please contact your dealer for any returns, repairs or support issues related to this product.
Price: 1249.5 USD
Location: 8721
End Time: 2024-11-23T19:25:25.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Victron Energy
Type: LYN034170210
MPN: LYN034170210