Description: CMS9200 ICU Patient monitor 15'' TFT color LCD, 15-language ECG,RESP,SpO2,PR,NIBP,TEMP Introduction Introduction This device can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for patient moving. Functions Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP 1)ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis 2)RESP Respiration rate(RR) Respiration waveform 3)SpO2 Pulse oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph 4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN) 5)TEMP T1, T2, TD It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc. Features 1)15'' TFT color LCD, 15-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech). 2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection. 3)All-round monitor for adult, pediatric and neonate. 4)With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe. 5)Waveform, parameter color and location can be set optionally. 6)Operation mode: keys and buttons. 7)Display up to 8-channel waveform on one screen. 8)Display 7-lead ECG waveform on one screen, and with ECG step function. 9)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling. 10)HRV analysis function. 11)NIBP measurement mode: Manual/AUTO/Continuous, storage for 4800-group NIBP data. 12)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events. 13)Drug concentration calculation and titration table functions. 14)Print trend table data with one-key. 15)Connect to Central Monitoring System by 3G, WiFi or wired mode. 16)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring. 17)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary). Performance ECG Lead mode: 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-channel 3-lead, 1-channel Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range: 15~350bpm Accuracy: ±1% or ±1bpm, whichever is greater Alarm accuracy: ± 2 bpm Resolution: 1 bpm ST-segment monitoring: Measurement and alarm range: -2.0mV~+2.0mV Accuracy: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker: yes RESPIRATION Method: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150rpm Resolution: 1 rpm Measurement accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s NIBP Method: Oscillometry Mode: Manual/AUTO/Continuous Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes Measurement period in Continuous mode: 5 minutes Measurement and alarm range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ±3 mmHg Measurement accuracy: Maximal mean deviation: ±5 mmHg Maximal standard deviation: 8mmHg Over-pressure protection: Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg SpO2 Measurement and alarm range: 0 ~ 100% Resolution: 1% Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified PR Measurement and alarm range: 30 ~ 250 bpm Measurement accuracy: ±2 bpm or ±2%, whichever is greater TEMP Channel: dual-channel Measurement and alarm range: 0 ~ 50℃ Resolution: 0.1 ℃ Accuracy: ±0.1 ℃ EtCO2(optional) Method: Sidestream or Mainstream Measurement range for CO2: 0~150mmHg Resolution for CO2: 0 ~ 69 mmHg: 0.1 mmHg 70 ~ 150 mmHg: 0.25 mmHg Accuracy for CO2: 0 ~ 40 mmHg: ±2 mmHg 41 ~ 70 mmHg: ±5% 71 ~ 100 mmHg: ±8% 101 ~ 150 mmHg: ±10% AwRR range: 2~150 rpm AwRR accuracy: ±1 rpm Apnea alarm: yes IBP(optional) Channel: dual-channel Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and alarm range: -10~300 mmHg Resolution: 1 mmHg Accuracy: ±2% or 1mmHg, whichever is greater Power supply:AC 100-240V, 50/60Hz Safety classification: Class I, type CF defibrillation-proof applied part Accessories Adult fingertip SpO2 probe (5-pin) Adult NIBP cuff NIBP extension tube ECG lead cable ECG electrode Temperature probe Power cord User Manual Physical characteristic Dimension: 363 mm(L) × 168 mm(W) × 339 mm(H) Weight: 4.9 Kg Buy safe products The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved International Buyer--Please note: Import duties,Taxes are not included in the item price.These charges are buyers' responsibility We are the manufacturer of medical equipment for 17 years, the following are our main products: ECG / ECG holter EEG / EEG Holter B-ultrasound Patient Monitor Fetal doppler Fetal Monitor Spo2 Monitor Stethoscope Medical Image.... Agent in the world! We are look for partners in the world now! Do you want to become our agent in you conutry? Join US! Sky--pe:xuebox3 Only English User Manual,Please contact us if you need other language version.thank you Only English User Manual,Please contact us if you need other language version.thank you
Price: 699 USD
Location: beijing
End Time: 2023-11-30T10:27:02.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: CONTEC
MPN: 658126
Monitor Parameters: Blood Pressure - NIBP, ECG, O2 - SpO2, Respiratory Rate, Temperature
Technology: Digital
Model: CMS9200
Screen Dimensions: 15'' TFT color LCD
Country/Region of Manufacture: China