Description: 1PC Glassy Carbon Electrode 3MM Glassy Carbon Electrode model:Imported 3mm glassy carbon electrodeImported 4mm glassy carbon electrodeImported 5mm glassy carbon electrodeGlassy carbon, short for glassy carbon, is the slow heating of polyacrylonitrile resin or phenolic resin to high temperature in inert atmosphere.(reach1800Temperature)The glass-like amorphous carbon is suitable as an electronic conductor material for electrodes and is widely used in table tennis baseboard. Glassy carbon electrode is the abbreviation of glassy carbon electrode. The advantages of glassy carbon electrode are good conductivity, high chemical stability, low thermal coefficient, hard texture, good air tightness and wide potential application range.(About obedience-1651VRelative to saturated calomel electrodes)It can be made into cylindrical, disc and other electrode shapes. It can also be used as a matrix to make mercury film glassy carbon electrode and chemically modified electrode. It has been widely used in electrochemical experiments or electroanalytical chemistry. Electrode characteristics: Glassy carbon electrode is one of the widely used working electrodes. It is a good inert electrode with good electrical conductivity, high hardness, high polish, high hydrogen overpotential, wide polarization range and chemical stability. It can be used as inert electrode directly for anodic dissolution, voltammetric determination of cathode and valence ion, and can also be used as chemically modified electrode. Electrode treatment and maintenance: The glassy carbon surface must be mirror and clean. Because the surface of glassy carbon is easily polluted by some organic metal compounds, which seriously affects the measurement (no peak, no miscellaneous peak, no recurrence), it must be cleaned before measurement. There are three main methods, chemical method.1.Nitric acid soaking and scrubbing.2.with Ammonia water anhydrous ethanol or ethyl acetate1:1Soak and scrub.3.Alcohol can also be used after scrubbing and then with6NHCLor4NHO3Soak. Electrochemical treatment: i.e.+0.8V-(-1.8V(0.5MKcLPH7exceptO2IRepeated Polarization (Reset) in Voltage Range-Scanning (Anode)-If the cathode is seriously polluted and pitted, scratches can be treated mechanically.MgOPowder(200Put it on wet velvet cloth and polish it with a little water. Also Several methods are combined according to the condition of electrodes. It is not advisable to immerse the electrode in strong acid, alkali and organic solvents for a long time. Because glassy carbon electrodes are inert electrodes, they are scanned electrodes using scanned materials, such as mercury, copper, gold, mercury, copper and gold film electrodes. For example, there are two kinds of mercury plating: anodic stripping and gold plating, glassy carbon mercury plating: the first is isotopic mercury plating, that is, adding a certain amount of mercury to the sample being analyzed.Hg+Mercury oxide and mercury nitrate are usually used to electrolytically enrich the sites to be ionized, and mercury amalgam is formed at the same time. After scanning and dissolution, the ions or mercury film to be measured can be completely dissolved at a positive potential. The mercury film can also be wiped off with filter paper. In order to ensure the reproducibility of the second analysis, the surface of the electrode is still in its original state. The concentration of mercury ion is generally the concentration of the measured ion.500-1000The second is to deposit mercury film.1.Mercury was electrodeposited for a long time at the positive ion electrolytic potential to be measured. As measuredcuAvailable in-0.2VPrevent electrowinning by electrowinning mercury film for a long timecu,pb,cd,znThe danger is that this method is inefficient and takes a long time.2.Under the condition of isotopic mercury plating, after electrowinning for a period of time, scanning dissolution, dissolution at the termination potential for a general time, dissolution of the ions to be measured, so enriched.-A layer of mercury film without ions to be measured can be obtained by dissolution several times. as0.5MKCL+2-times; 10-2MHg+more than ten drops of saturated NaSO3 were enriched in-1.4V stirring for 5-10 minutes, scanned to-0.1V in 15 seconds under stirring condition, stirred to dissolve for 30 seconds under-0.1V, stirred to concentrate for 5-10 minutes under reset condition, stirred to scan to-0.1V in 15 seconds, stirred to dissolve for 30 seconds under-0.1V, stirred to dissolve at rest, removed the electrode rod and washed with water to prevent the coating from breaking. When plating mercury, it should be noted that there is no bubble under the electrode to absorb, otherwise the mercury coating is uneven and the electroplating can not be achieved. In the short term, the electrode can not be soaked in 1:1 nitric acid, and then washed and plated when used. In the long run, it should not be washed and dry preserved without mercury removal. The basic principle of glassy carbon gold plating is the same as mercury plating. Packing: 1PCWarranty period: 120 days
Price: 41.53 USD
Location: 深圳
End Time: 2025-01-26T01:37:14.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Unbranded
MPN: Glassy Carbon Electrode
Model: 972133
Marca: NONE
Tipo: NONE
Marque: NONE
Decoration and construction content: Hydropower Engineering
Available Variations
Color: Imported 3mm glassy carbon electrode
Price: 41.53 USD
Available Quantity: 3
Quantity Sold: 2
Color: Imported 4mm glassy carbon electrode
Price: 80.76 USD
Available Quantity: 2
Quantity Sold: 1
Color: Imported 5mm glassy carbon electrode
Price: 107.69 USD
Available Quantity: 1
Quantity Sold: 0