Description: FRN010G1S-4U Fuji FRENIC-MEGA 10HP Inverter/Variable Frequency Drive, 480VAC Single or 3-Phase Input, 480VAC 3-Phase Output Description Fuji Electric’s FRENIC-MEGA drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1/2 HP through 1000 HP motors. They are designed for 24/7 operation with embedded motor protection and critical maintenance functions. Fuji Electric's FRENIC-MEGA continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the FRENIC-MEGA series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications. The FRENIC-MEGA series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity. Specifications Manufacturer Fuji Electric Model Number FRN010G1S-4U Enclosure UL/NEMA Open Type IP20 Input Voltage 380 to 480 VAC 50/60Hz Single or Three Phase Output Voltage 380-480 VAC Three Phase HP Rating 10 HP Rated Current 16.5 Amps Weight 14.3 lbs Warranty 3 Years from date of shipment Detailed Specifications Output Ratings: Nominal Applied Motor (Rated Output) 5 HP with Single Phase Input (LD Mode) 10 HP with 3-Phase Input (LD Mode) 3 HP with Single Phase Input (HD Mode) 7.5 HP with 3-Phase Input (HD Mode) Rated Output Capacity 8.8 kVA with Single Phase Input (LD Mode) 13.1 kVA with 3-Phase Input (LD Mode) 6.4 kVA with Single Phase Input (HD Mode) 11 kVA with 3-Phase Input (HD Mode) Rated Output Current 11.0 Amps with Single Phase Input (LD Mode) 16.5 Amps with 3-Phase Input (LD Mode) 8.0 Amps with Single Phase Input (HD Mode) 13.5 Amps with 3-Phase Input (HD Mode) Rated Voltage Three Phase, 380-480VAC (with AVR function) Output Overload Capability LD Mode: 120% for 1 Minute HD Mode: 150% for 1 Minute, 200% for 3 Seconds (Overload capability interval: IEC 61800-2 compliant) Output Frequency V/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD/LD Mode) Sensorless Vector Control: 0-120Hz Closed Loop Vector Control: 0-200Hz Output Stability Analog Setting: ±0.2% of Maximum Frequency Digital Setting: ±0.01% of Maximum Frequency (By Keypad) Input Ratings: Rated Input Frequency 50/60 Hz +/-5% Rated Input Voltage 380 to 480VAC +10%/-15% Rated Input Current 23.2/17.3 Amps (Single Phase Input, LD/HD) 20.1/15 Amps (3 Phase Input, LD/HD) 15.7/11.7 Amps (Single Phase Input with DCR, LD/HD) 12.5/9.2 Amps (3 Phase Input with DCR, LD/HD) Required Input Power Supply Capacity 7.3/5.4 kVA with Single Phase Input with DCR (LD/HD) 10/7.4 kVA with 3-Phase Input and DCR (LD/HD) Braking: Braking Torque 70% (LD Mode) 100% (HD Mode) Braking Transistor Built-In Braking Resistor Built-In Braking Time 3.7 Seconds (LD Mode) 5 Seconds (HD Mode) ED 2.2% (LD Mode) 3% (HD Mode) DC Reactor Optional Other: Keypad Multi-function Keypad Safety Standards UL508C, C22.2 No.14, EN61800-5-1:2007 Enclosure IP20, UL Open Type Cooling Method Fan Cooling Weight/Mass 14.3 lbs 6.5 kg Ambient Temperature NEMA/UL Open/Type 1: -10 to 50°C (14 to 122°F) Storage Temperature -25 to 65°C (-13 to 149°F) Relative Humidity 5 to 95% RH (Without Condensation) Installation Location IEC60664-1 Pollution Degree 2 (Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight) Indoor Use Only Safety EN ISO13849-1, EN954-1, Category 3 Standards UL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007 CE: EN61800-5-1 RoHS: 2002/96/EC Altitude 0 to 3,300ft (1,000m) 3,300ft (1,000m) to 9,900ft (3,000m) with Derating Features Control Inputs & Outputs 9 Digital Inputs: X1 – X7 2 Safety Input (Dedicated): EN1, EN2 3 Analog Inputs 6 Digital Outputs: (2) Relays (1 Form C & 1 Form A) & (4) Transistor 56 Selectable Functions 2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA Can be Configured to Provide Output Signal Proportional to 15 Different Functions 2 RS-485 Connections: RJ45 Keypad Port & Control Terminal Block Connections 24VDC Output Terminal Rated 100mA High Performance LED & LCD Keypad with NEMA/UL Type 4 Approval Robust Design Nickel (Ni) & Tin (Sn) Plated Bus Bars Cooling Fan Board Coating and Anti-Rust Protection 10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal Flexibility & Functionality Removable Control Terminal Block PC Programming & Troubleshooting Software Customizable Logic 3 Option Card Ports Built-In Heatsink can be mounted through the back of an enclosed design Motor Control Multiple Power Ratings: LD (Low Duty): 120% for 1 Min MD (Medium Duty): 150% for 1 Min HD (High Duty): 200% for 3s / 150% for 1 Min High Performance Closed Loop Vector Control with Option Card High Performance Sensor-less Vector Control Built-in Braking Transistor Up to 40HP(LD)/30HP(HD) Built-in Braking Resistor up to 15HP(LD)/10HP(HD) Single Phase Input for All Models Safety & Standards Safety Input Compliant with EN ISO13849-1, EN954-1, Category 3 UL 508C, CE UL Plenum Rating RoHS Directive Compliance NEMA/UL Type 1 by Option Kit Options Communication Expansion Options: Ethernet (OPC-ETH) CC-Link (OPC-G1-CCL) DeviceNet (OPC-G1-DEV) Profibus DP (OPC-G1-PDP/OPC-G1-PDP2) CANopen (OPC-G1-COP) T-Link (OPC-G1-TL) I/O Expansion Options: Keypad with USB Port (TP-E1U) Relay Output (OPC-G1-RY) Digital Inputs (OPC-G1-DI) Digital Outputs (OPC-G1-DO) Analog Inputs and Outputs (OPC-G1-AIO) PG (Encoder) (OPC-G1-PG 12V / OPC-G1-PG2 5V) PG Synchronization (OPC-G1-PG22) Other Expansion Options: DC/AC Reactor CE Filter Braking Unit Braking Resistor NEMA/UL Type1 Kit Dimensions W 8.66" 220 mm W1 7.72" 196 mm W2 0.39" 10 mm H 10.24" 260 mm H1 9.37" 238 mm H2 0.43" 11 mm D 7.68" 195 mm D1 4.13" 105 mm D2 3.54" 90 mm D3 0.39" 10 mm øA 0.39" 10 mm Fuji’s original dynamic torque vector control has further evolved. Besides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz. Improved durability in overload operation The inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment. Overload durability: 200% for 3 sec and 150% for 1 min. The standard model is available in two specifications concerning the operational load. Classification Overload current rating Major use HD (High duty) spec 200% for 3 sec, 150% for 1 min Operation under heavy load MD (Middle duty) spec 150% for 1 min Operation under constant torque load LD (Low duty) spec 120% for 1 min Operation under light load Expanded capacity for the braking circuit built-in type A braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery. (7.5kW or smaller models also incorporate a braking resistor.) * Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series. Maximizing the performance of a general-purpose motor Speed sensor-less vector control Useful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower. Speed control range: 1:200 Speed response: 20Hz Speed control accuracy: ±0.5% Current response: 500Hz Torque accuracy: ±10% Improved reaction to the fluctuation of impact load When a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine. Quicker response to the operation commands The terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time. This function is effective in shortening the tact time per cycle in processes which include frequent repetitions. Convenient function for operations at the specified speed The pulse train input function is equipped as standard. It is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz) Ratio operation The ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily. Thorough protection of the braking circuit The inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit. Optimum function for preventing an object from slipping down The reliability of the brake signal was increased for uses such as vertical conveyance. Conventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily. Dancer control function optimum for winding control The PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller. More functions are available to meet various requirements (1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal (2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.) (3) Non-linear V/f pattern at 3 points (4) Dummy failure output function (5) Selection of 4 motors (6) S-shape accel./decel. range setting (7) Detecting disconnection of the PID feedback Advanced network function RS-485 communications is possible as a standard function (terminal base). Besides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made. Designed life 10 years The designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles. Consumable part Designed life Main circuit capacitor 10 years Electrolytic capacitor on PCB 10 years Cooling fan 10 years The conditions used for the calculation of the parts' life are: an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed. Full support of life warnings The inverter is equipped with the functions for facilitating the maintenance of the equipment. Item Purpose Cumulative inverter run time (h) Displays the total run time of the inverter. Number of inverter startups Displays the number of times the inverter has started the equipment. Example of use: This data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load. Equipment maintenance warning Cumulative run time (h) Number of startups By inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured. This makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule. Display of inverter life warning The displayed contents include: main circuit capacitor capacity, total run time of the cooling fan (with ON/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter. Compliance with RoHS Directives MEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE) About RoHS: The Directive 2011/65/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.
Price: 883.47 USD
Location: Stevens, Pennsylvania
End Time: 2024-10-07T17:07:12.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: FUJI ELECTRIC
MPN: FRN010G1S-4U