Description: Fluke 773 Milliamp Process Clamp Meter Milliamp process clamp meters can measure mA signals without breaking the loop. The Fluke 773 mA Clamp Meter is Fluke’s premier mA Clamp Meter, providing you with the best in troubleshooting and process calibration power.Need more hours in your day? Save time by NOT breaking the loop on 4-20 mA signal measurements. Are you spending time: Taking mA measurements by removing a wire and breaking the loop Calling the control room to isolate a loop Testing analog input/output on a console Troubleshooting devices with mA inputs and outputs Repairing intermittent or erratic 4-20 mA loops Going back to the shop to get extra tools If you need more time in your busy day take a good look at the Fluke 773mA Clamp Meter. It’s designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system. Here are some specific ways the Fluke 773 Clamp Meters will help you: Milliamp Clamp FeaturesApplicationHow it saves time and moneyMeasure mA signals for PLC and control system analog I/O without breaking the loop.Measures low level dc currentCorrelate process indication with real physical valueMeasure output signals from transmitters without breaking the loopMaintain and troubleshoot process and automation equipment without breaking the loopNo disruption to the processDetachable clamp with extension cableMeasurements in tight locationsEnables measurements in difficult situationsSource, simulate and measure mA signals in circuit (break the loop)Confirm non-contact measurement. ve the next tool in hand for troubleshooting (source simulate)Eliminates the need to return to the shop to get a loop calibrator for troubleshooting after finding a bad signal with non-contact measurementSource and measure VDCTroubleshoot voltage input and output devices.Measure presence of 24V loop power. Measure 1 to 5 or 0 to 10V process signals. Test chart recorders4 to 20 mA In/outDual channel mA source and measurement for troubleshootingSource 4 to 20 mA signals into valves and mA signal conditioners and simultaneously measure 4 to 20 mA positioning output signals.4 to 20 mA scaled outputScaled mA output provides a mA signal output representative of the measured mA valueConnect a logging DMM and log the mA signal without breaking the loopLoop power supplyPower a transmitterSubstitute testing of the installed 24V loop power supply. Power a transmitter and measure its mA output signal for troubleshooting.Dual backlit display with both mA measurement and percent of 4 to 20 mA spanClear measurement presentationAllows quick measurement evaluationMeasurement SpotlightIlluminates hard to see wires in dark enclosuresMeasurement process is easier and quickerMeasure up to 99.9 mA range non-contactWide range of measurementsMeasures 10 to 50 mA signals in older control systemsAutomatic power offAfter 15 minutes and 2 minute automatic off for backlight and spotlightSaves battery life The 773 mA Clamp Meter features: Best in class 0.2 % accuracy 0.01 mA resolution and sensitivity Measure 4 to 20 mA signals without ”breaking the loop” Measure mA signals for PLC and control system analog I/O Dual backlit display with both mA measurement and percent of 4 to 20 mA span Measurement Spotlight illuminates hard to see wires in dark enclosures Detachable clamp with extension cable for measurements in tight locations Measure 10 to 50 mA signals in older control systems using the 99.9 mA range Automatically change the 4 to 20 mA output for remote testing Power saving features, auto-off, backlight timeout extend battery life Hold function captures and displays changing measurements Measure 4 to 20 mA signals with in-circuit measurement Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters Source 4 to 20 mA signals for testing control system I/O or I/Ps mA output linear ramp or 25% step output Automatically change the 4 to 20 mA output for remote testing DC voltage measurement to verify 24V power supplies or voltage I/O signals Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp Enables milliamp signal logging to a separate logging device without breaking the loop Output mA signal enables a logging DMM or other device to record the 4- to 20 mA signal without breaking the loop mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal Apply a mA input signal to a device and measure its’ 4-20 mA output on devices such as valves or mA isolators Voltage output linear ramp or 25% step output Automatically change the voltage output for remote testing What’s the difference between the 77X models? *Fluke-771Fluke-772Fluke-773 *Non-contact mA loop measurementIntegrated mA loop troubleshootingAdvanced process troubleshootingmA measure, jaw mA measure, in circuit * Loop power * mA source * DCV measure * * DCV source * * mA scaled output * * mA in / out * * Environmental SpecificationsDiameter of measurable conductor0.177” or 4.5 mm maxOperating temperature-10 to 50 ºCStorage Temperature-25 to 60ºCOperating Humidity< 90% @ <30 ºC, < 75% @ 30 to 55ºCOperating Altitude0 to 2000 mIP RatingIP 40Size44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)Weight410 g, (14.4 oz)VibrationRandom 2 g, 5 to 500 HzShock1 meter drop test (except the jaw)EMI/RFIMeets EN61326-1 Note: For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.Temperature Coefficient0.01% ºC (<18ºC or > 28ºC)Power, battery life(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohmsWarrantyThree years for electronics one year for cable and clamp assembly Functional SpecificationsmA measurement (Measured by clamp) 771/772/773Resolution and Range: 0 to 20.99 mA Accuracy: 0.2%+2 counts Resolution and Range: 21.0 mA to 100.0 mA Accuracy: 1% + 5 countsmA measurement (Measured in series with test jacks) 772/773Resolution and Range: 0 to 24.00 mA Accuracy: 0.2% + 2countsmA source (Maximum mA Drive: 24 mA into 1,000 ohms)Resolution and Range: 0 to 24.00 mA Accuracy: 0.2% + 2countsmA simulate (Maximum voltage 50 V dc)Resolution and Range: 0 to 24.00 mA Accuracy: 0.2% + 2countsVoltage source (2 mA maximum drive current)Resolution and Range: 0 to 10.00 V dc Accuracy: 0.2% + 2countsVoltatge MesaureResolution and Range: 0 to 30.00 V dc Accuracy: 0.2% + 2counts Notice:The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.Thanks for your suppor
Price: 952 USD
Location: shenzhen
End Time: 2024-07-31T04:27:09.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Measurement Category: CAT III
Brand: Fluke
Form Factor: Handheld
Test/Measurement Functions: AC Voltage, AC Current, DC Voltage
IP Rating: IP40
Features: Clamp, True RMS
Protection Against Solids: Dust Protected
Input Protection Features: Clamping Circuit
Display: Digital