Description: Elimia DOL Magnetic Motor Starter. Works in all applications where a separate limit switch is not used to engage the starter. UL 508A CertifiedEvery Motor Starter is built and tested to order in Alabama, USA. Our customer's come back time and time again, try one and you will see... Nothing else in this price range even comes close. We have updated our enclosed motor starters to make them better than ever. Now using Nema Rated LSis Motor Starter, made in Korea. Also, the Weg control switch is new, it uses A600 type contact blocks.Please note that the label on the pictured unit may be from a different rated unit. Use the specifications below to verify for your application.Please call us if you have any questions. We want you to get the right equipment - 1-855-4Elimia. We offer an extensive line of standard motor starters as well as custom built units. Combination starters and reversing starters are also available in standard and custom configurations. This new magnetic motor starter is designed to run equipment where the user controls the starting and stopping. It uses momentary push buttons and a latch auxiliary contact on the starter to hold power until the stop button is pressed. This type of controls can not be used for equipment such as an air compressor. Pre-wired for easy installation.The unit will arrive completely assembled in a nice NEMA 4X polycarbonate enclosure. These enclosures are not like the competition's thermoplastic boxes. The top half of the enclosure is authentic polycarbonate and the bottom is blended ABS, fiber and polycarbonate. PG knockouts are provided for cordgrips or conduit. The design of the enclosure gives easy access to the motor starter making wiring up easier and allowing for a more compact unit. These enclosures are made in Europe by Ensto of Finland. The Motor Starter is made by LSis in Korea, it is both Nema and IEC rated.Model Number: DOL 4-6-480LCS Model Explanation: DOL = Across the line starter 4-6 = Overload Size 480 = Coil Voltage (suitable for 460V - 480V)LC = Low cost compact design Sized for 3 HP @ 460-480V 3 phase.In our ongoing effort to provide high quality, low cost products with as little as possible Chinese content - this assembly contains approximately 5-10% China material. Here is the major content country of origin:Contactor - LSis Korea Overload - LSis Korea Enclosure - Ensto Finland/Estonia Switch - Weg Brazil Indicator - Weg Brazil Assembly - Elimia United States AlabamaMotor starters are made up of primarily two parts. A contactor and overload device. Both devices have maximum ratings and the overload has maximum and minimum ratings. You should choose a motor starter that fits both criteria. If you need help please email or call, we will be glad to assist.To size your starter properly you must determine the following:-Three phase or Single phase-Supply voltage ie. 120V; 208V; 230V; 460V; 600V-Machine single motor HP-Motor FLA (full load Amps) and worst case SFA (service factor Amps)-Application, what type of machine you runningIf your supply Voltage is 208V and you want to use your supply power to power the contactor coil... Our 230V coils are rated down to 196 Volts. Now, under most cases our standard 230V coil will work flawlessly on 208V systems. But, if your machine is very large for your electrical service OR your wiring run is long or undersized I recommend using a separate 120V source for the coil power.Ratings of contactor used in this starter, do not exceed ratings:Size 12 Contactor, Nema Size 03 phase- 7.5 HP @ 480 VAC You must use a control voltage 460 - 480 VAC for this unit, it is pre-wired to connect to your line connections on the starter. The control voltage is the voltage used to activate the coil of the contactor. In the simplest install you will want a coil voltage the same as your power supply. But is some cases you might want the control voltage to be different for a host of reasons.The overload will have an adjustable Amperage range. Your overload choice is based on your machines FLA. If your machine motor has a FLA of 10 Amps at your supply voltage then you should choose the overload where 10 Amp falls within the adjustable range. For a 10 Amp FLA we would recommend overload 9 - 13 Amps. Some folks size overloads based on FLA times the Service Factor. So, if your service factor is 1.15, your SFA is 1.15 x FLA. In the example above it equals 10 FLA X SFA = 11.5 Amps.Our overloads can be set for manual or automatic reset operation. The overload control is pre-wired by Elimia in a way that trips the starter. This is done to protect your equipment and is one of the main purposes of a motor starter.Components mounted on a easy to remove back plate.Enclosure size is 7 x 5 x 5 90 day replacement Elimia warranty.Great price!We have pre-wired DOL motor starters available from 0 HP to 200 HP.Please call 1-855-4Elimia for more info or if we can help sizing a starter.Elimia has assembled and supplied thousands of starters to customers all over the world. In addition to our standard products we design and built custom control panels, VFDs, PLCs, container electrical systems, motor control centers etc... Our customers come back again and again for the value products we offer.Guarantee: Satisfaction Guaranteed! If you are not happy with your purchase within two weeks of arrival you can return it. No restocking fee! Offer excludes shipping and eBay fees. If the item has been installed and it turns out not be what you needed please call us. We will work with each customer and try to reach a resolution.There is no charge for on-sight pickup but 9% tax applies.Please note: All items should be professionally inspected and tested prior to installation or use. We are not liable for damages, injuries or death relating to our products.Payments: We accept Paypal and Credit Card payments. Credit card payments are only accepted over the phone.We reserve the right to refuse payment from buyers registered in foreign countries or locations with non corresponding ship to addresses. Additionally, we reserve the right to refuse payment from any buyer which will feel is acting in a possible malicious manner.Feedback: Once you are satisfied with your purchase please leave us feedback. If you have any problem with the transaction or product, please contact us. Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.
Price: 127 USD
Location: Fort Payne, Alabama
End Time: 2023-11-02T22:16:21.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Restocking Fee: 10%
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Enclosure Type: Enclosed
Model: DOL 4-6-480LCS
Modified Item: No
Country/Region of Manufacture: United States
Custom Bundle: No
NEMA Rating: 4X
Non-Domestic Product: No
UL Listed: Yes
Overload Trip Rating: 4-6 Amps
HP Rating: 3 HP @ 480V
Input Voltage: 460-480V
MPN: DOL 4-6-480LCS
Brand: Elimia