Description: CMS8000 Patient Monitor Introduction The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~,50/60Hz, adopts 12.1'' color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system. This device can monitor such parameters as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving. Functions Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP 1)ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis 2)RESP Respiration rate(RR) Respiration waveform 3)SpO2 Oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph 4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN) 5)TEMP T1, T2, TD 6)IBP(optional) CH1:SYS,DIA,MAP CH2:SYS,DIA,MAP IBP waveform 7)CO2(optional) EtCO2 InsCO2:Inspired Minimum CO2 AwRR:Air Way Respiration It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc. Features 1)12.1'' TFT color LCD, multi-language interface(English,French,German,Italian,Dutch,Russian,Portuguese ,Turkish,Spanish(EU),Polish,Romania,Kazakh,Czech,Trad Chinese,Spanish(MX),Bulgarian,Chinese, Ukraine). 1)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection. 2)All-round monitor for adult, pediatric and neonate. 3)With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe. 4)Finish all operations by keys and knobs. 5)Maximum 8-channel waveform synchronous display. 6)Display 7-lead ECG waveform on one screen, cascade ECG waveform display 7)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling. 8)Heart rate variability (HRV) analysis function 9)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data. 10)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events. 11)Drug concentration calculation and titration table functions. 12)One-touch printing of trend graph 13)Connect to Central Monitoring System by 3G, Wi-Fi or wired mode. 14)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring. 15)Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary). Performance ▲ECG Lead mode: 3-lead:I, II, III 5-lead:I, II, III, aVR, aVL, aVF, V Waveform: 3-lead, 1-channel 5-lead, 2-channel Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV Scan speed: 12.5 mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range: 15~350 bpm Resolution: 1 bpm Accuracy: ±1 % or ±1 bpm, whichever is greater Alarm accuracy: ± 2 bpm ST-segment monitoring: Measurement and alarm range: -2.0 mV~+2.0 mV Accuracy: -0.8 mV~+0.8 mV:±0.04 mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker: yes ▲RESP Method: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150 rpm Resolution: 1 rpm Measurement accuracy: 7 rpm~150 rpm, ±2 rpm or ±2%, whichever is greater; 0 rpm~6 rpm, no definition; Apnea alarm: 10~40 s Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s ▲NIBP Method: Oscillometry Mode: Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes Measurement period in STAT mode: 5 minutes Measurement and alarm range: 10~270 mmHg Resolution: 1 mmHg Cuff pressure accuracy: ±3 mmHg Measurement accuracy: Maximal mean deviation: ±5 mmHg Maximal standard deviation: 8 mmHg Over-pressure protection: Adult mode: 297 mmHg±3 mmHg Pediatric mode: 240 mmHg±3 mmHg Neonatal mode: 147 mmHg±3 mmHg ▲SpO2 Measurement and alarm range: 0~100 % Resolution: 1 % Accuracy: 70~100 %: ±2 % 0~69 %: unspecified ▲PR Measurement and alarm range:25~250 bpm Measurement accuracy: ±2 bpm or ±2 %, whichever is greater ▲TEMP Channel: dual-channel Measurement and alarm range: 0~50℃ Resolution: 0.1 ℃ Accuracy: ±0.1 ℃ ▲EtCO2 Method: Sidestream or Mainstream Measuring Range: 0~150 mmHg Resolution: 0~69 mmHg: 0.1 mmHg 70~150 mmHg: 0.25 mmHg Accuracy: 0~40 mm Hg: ±2 mm Hg 41~70 mm Hg: ±5 % 71~100 mm Hg: ±8 % 101~150 mm Hg: ±10 % AwRR Range: 2~150 rpm AwRR Accuracy: ±1 rpm Apnea Alarm: Yes ▲IBP Channel: dual-channel Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and Alarm Range: -10~300 mmHg Resolution: 1 mmHg Accuracy: ±2% or 1mmHg, whichever is greater ▲Power supply: 100-240V~, 50/60 Hz ▲Safety classification: Class I, type CF defibrillation-proof applied part ▲Harmful liquid proof degree: IPX2 Accessories 1)Adult fingertip SpO2 probe (5-pin) 2)Adult NIBP cuff 3)NIBP extension tube 4)ECG lead cable 5)ECG electrode 6)Temperature probe 7)Power cord 8)User Manual Physical characteristic Dimension: 319 mm(L) × 167 mm(W) × 268 mm(H) Weight: <3.0 kg(excluding accessories) About Us Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you. Shipping 1.Our shipping rates include the cost of shipping, handling, packaging,custom fees are not included,buyers pay the taxes. 2.We usually shipped out the items the next business day after payment has been verified (Sat. & Sun. excluded.) Contact Us Please contact us first if you are not satisfied with the item when you receive it or haven't received item after 30 days, We will try our best to solve any problem. Open case and negative feedback is not conducive to solve the problem for both sides. hope you can understand! All emails will be answered within 24 hours on weekdays(but within 48hours on weekends).Please don't hesitate to contact us with any queries or comments about our items or your problem. Only English operating instruction,if you need any other language,please contact us!
Price: 898 USD
Location: Elk Grove Village, Illinois
End Time: 2023-08-05T06:17:45.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: CONTEC
MPN: Does Not Apply
Monitor Parameters: Blood Pressure - NIBP, ECG, O2 - SpO2, CO2
Intended Use/Discipline: Biological Laboratory, Dental Laboratory, Emergency Medicine
Features: Battery Operated, Handheld
Technology: Digital
Model: CMS8000
Country/Region of Manufacture: China