La Milano

3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter

Description: 3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter This is a used 3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter that is tested and working. Includes: 3M Dynatel 2273 Pipe Locator 3M Dynatel 2273 transmitter Ground Stake Lead The 3Mル Dynatelル 2273 Fault Locator is a microprocessor-based system that incorporates advance digital signal processing techniques to quickly and efficiently locate sheath (earth return) faults and trace the path of underground cables, both copper and fiber optic (with metallic trace wire). Lightweight, compact and wellbalanced, the 2273 cable/fault locator accurately: Locates cable path Measures cable or sonde depth with the push of a button Measures signal current in the cable Pinpoints sheath faults and cable breaks Discriminates between light and heavy faults Identifies cable and cable pairs Tones shorts and grounds in aerial cable Identifies cable pairs through wet sections Locates energized power cable The 2273 cable/fault locator provides accurate cable or sonde depth measurements, giving a digital readout in inches, feet and inches, or centimeters (user-selectable). Four modes of operation for accurate locates, even in congested areas For cable path locating, the Dynatel 2273 receiver uses one of four user-selected locating modes ラ dual peak, dual null, differential or special peak (which increases the sensitivity of the receiver for tracing over longer distances). The mode is selected depending on which is most effective under the locating conditions. The receiver includes four volume settings, including a special モexpanderヤ function that makes peaks and nulls more pronounced. The expander feature enhances the amplitude difference between two conductors carrying the same signal, making the unit extremely accurate, even in congested areas. A headphone jack is also included. Precisely locates faults The 2273 cable/fault locator can precisely locate sheath (earth return) faults on both short and long cable sections. The unit sends a trace signal simultaneously with a faultlocate signal, allowing the operator to use the cable-locate function when locating sheath faults in long cable sections. Sheath (earth return) fault strength is indicated on the receiver LCD display, allowing minor faults to be ignored, if desired. The Dynatel 2273 cable/fault locator is easy to operate and requires very little training. Digital liquid crystal display (LCD) readout and push-button operation make the unit easy to understand, for more precise locates. A モmemoryヤ feature remembers operator set-up from previous use. The system consists of three basic components: Transmitter with built-in ohmmeter, which also senses and measures the presence of foreign voltage, and tests the continuity of the circuit. One-piece hand-held receiver with bar graph that indicates received signal and proximity to the cable. Earth contact frame that is color-coded to correspond with indications from the receiver directing the operator toward the fault. The 2273 cable/fault locator uses four active trace frequencies ラ 577 Hz, 8 kHz, 33 kHz and 200 kHz ラ which can be used individually or simultaneously to compensate for varying field conditions. It also incorporates one passive trace frequency ラ 50/60 Hz power (userselectable) ラ which does not require the use of the transmitter. Both the receiver and the transmitter feature a self-test routine which is executed each time the unit is turned on. A power-up battery test indicates the battery level. Both components are constructed of heavy-duty materials designed to withstand typical field use. Features Benefits Transmitter Four operator-selectable frequencies Optimizes unit performance in varying conditions Simultaneous signals Enables receiver to verify cable location Fault-locate/cable-locate signals applied simultaneously Enables receiver to verify cable location while fault locating Built-in ohmmeter with voltage sensing/measuring capability Displays earth fault resistance; confirms far-end grounds and shield continuity Three signal application methods (direct connect, coupler, induction) Flexibility under varying plant conditions Auto load matching Automatic adjustment of output voltage to maximize signal High and normal output level High output level for extreme distance locates and other varying cable conditions Audible indication of hazardous voltage in ohms mode Warns operator of potentially dangerous situation Can connect to energized power cables up to 240 Vac Prevents inadvertent damage to unit; operates while attached to live circuits Receiver Peak and null modes Verify cable location Differential mode Indicates direction to cable Push-button digital depth readout (of cable or sonde) in inches, feet and inches, or centimeters Easy, quick and accurate depth measurements; no conversion table required for sonde depth measurements Measures signal current in cable Helps identify target cable regardless of depth Visual and audible cable locates Ensure accuracy under varying field conditions Digital fault strength indicator Operator can differentiate between light and severe faults Coupler jack Pair/cable identification Graphic display Operator can distinguish between target cable and other cables in congested areas Expander function Improves sensitivity of audible and visual response 50/60 Hz passive power mode Locates energized power cables using receiver only Compatible with 2205/2206 marker locating accessory Allows unit to pinpoint location of buried EMS markers Physical Specifications Size Transmitter 6.75 H x 11.25" W x 7.75" D (17.2 cm x 28.6 cm x 19.7 cm) " Receiver 25.5 H x 3.75" W x 10.75" D (64.8 cm x 9.5 cm x 27.3 cm) " Weight Transmitter 5.88 lbs. (2.4 kg) Receiver 3.98 lbs. (1.8 kg) Shipping 20.59 lbs. (9.3 kg) Environmental Specifications Operating temperature -4° to 122°F (-20° to 50°C) Storage temperature -40° to 158°F (-40° to 70°C) Electrical Specifications Receiver Frequencies Trace mode Tone mode Active: 577 Hz, 8 kHz, 33 kHz, 200 kHz Passive: Power ラ 50/60 Hz, user-selectable 577 Hz and 200 kHz pulsed at 8 Hz Depth Range: 0 to 15メ (0 to 4.5 m) Accuracy: ±10% ±1 digit for 0 to 60 (0 to 1.5 m) ±15% for 60 to 180" (1.5 to 4.5 m) " Power Six alkaline モAAヤ (LR6) cells Typical battery life 50 hours Transmitter Output frequencies Trace mode Sheath fault mode Tone mode Induction mode 577 Hz, 8 kHz, 33 kHz, 200 kHz 4/8 Hz for sheath fault; 577 Hz and 33 kHz for tracing 577 Hz and 200 kHz pulsed at 8 Hz 200 kHz Output voltage (maximum) Sheath fault Trace Tone 75 Vrms 40 Vrms Normal setting: 10 Vrms High setting: 75 Vrms @ 577 Hz; 40 Vrms @ 200 kHz Output power Normal setting: Limited to 0.5 W High setting: Limited to 3 W for frequencies < 200 kHz and 200 kHz in induction mode; 1 W for 200 kHz (non-induction) Output protection 240 Vrms Power Six alkaline モCヤ (LR14) cells Typical battery life Normal output level: 50 hours High output level: 10 hours

Price: 1794 USD

Location: Katy, Texas

End Time: 2024-11-28T17:55:53.000Z

Shipping Cost: 0 USD

Product Images

3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter3M Dynatel 2273 Cable Pipe Fault Locator and Transmitter

Item Specifics

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money Back

Return policy details:

Brand: 3M Dynatel

MPN: EV5142

Recommended

3M™ Dynatel™ Locator 1420X EMS/ID For parts only - not working
3M™ Dynatel™ Locator 1420X EMS/ID For parts only - not working

$399.00

View Details
3M Dynatel 745 Compact Telephone Subscriber Loop Tester
3M Dynatel 745 Compact Telephone Subscriber Loop Tester

$81.70

View Details
NEW 3M Dynatel 2210 2250 2273 2573 2550 DIRECT CONNECT LEADS LOCATOR
NEW 3M Dynatel 2210 2250 2273 2573 2550 DIRECT CONNECT LEADS LOCATOR

$129.95

View Details
3M 7000031432 | 9011 coupler cable (Free Shipping)
3M 7000031432 | 9011 coupler cable (Free Shipping)

$275.00

View Details
LOT of 2 - 3M Dynatel Power Cable / Fault Locator
LOT of 2 - 3M Dynatel Power Cable / Fault Locator

$120.00

View Details
3M Dynatel 2220L Cable / Pipe Locator
3M Dynatel 2220L Cable / Pipe Locator

$155.00

View Details
3M Dynatel 2273 Cable Pipe Fault Locator 2273-U3P3
3M Dynatel 2273 Cable Pipe Fault Locator 2273-U3P3

$2489.00

View Details
3M DYNATEL Battery Holder & Cap for  2573 2273 2550 2250 1420 7420 ALL M Series
3M DYNATEL Battery Holder & Cap for 2573 2273 2550 2250 1420 7420 ALL M Series

$19.95

View Details
3M Dynatel 573A/P  Sheath Fault/Earth Cable Ground Locator For PARTS/REPAIR 281A
3M Dynatel 573A/P Sheath Fault/Earth Cable Ground Locator For PARTS/REPAIR 281A

$99.99

View Details
3M Dynatel 4121 APICS Automatic Pair Identification & Cable Status System AS-IS
3M Dynatel 4121 APICS Automatic Pair Identification & Cable Status System AS-IS

$899.00

View Details